Retained to aid and assist with the reinforcement and jet grouting of a collapsed coal mine located between 36m and 30m below surface.
Jet Grouting of a collapsed coal mine located between 36m and 30m below surface:
- Pre-drilling of 10” reflow conduits 24m deep each
- Double fluid Jet Grouting of up to 30m3 per hole between 36m and 30m
- Spoil and reflow management of up to 50m3 per day
- Working in sub-zero temperatures up to -40 degrees Celsius
- Working adjacent to 500kV overhead lines
- Cement Bentonite grout mix for compressive strength control and to minimize bleed.
See similar projects
Brightside Phases 1 and 3
The project involved various complex tasks such as drilling and installation of cased secant piles, excavation and offsite disposal of soil, installation of tie-back anchors, and shotcrete wall construction.
Learn moreKITS BLOCK - 1981 Macdonald Street, Vancouver
Matcon successfully completed bulk excavation, disposal of contaminated soils, and extensive shotcrete shoring, overcoming challenges posed by hard sandstone with dedicated overtime efforts to maintain the project schedule.
Learn more3619 - 3681 Arbutus Street
Matcon successfully navigated unique challenges, including Vancouver's winter weather and absorbent sandy soils, to complete bulk excavation and shoring, managing running groundwater and implementing face-saving measures within budget and on time.
Learn moreSeymour Village Phase 6
Matcon successfully executed excavation and shoring for the Seymour Village Phase 6 residential project, navigating challenges near active townhome communities with a focus on safety and minimal neighborhood impact.