An intricate project requiring contaminated soil management, temporary road reinstatements and managing operations around high voltage overheas lines.
Supply/Installation Jet grout columns for ground improvement for 3 TBM maintenance stations
- Installation of over 100 Jet Grout Columns, up to 63m deep at 3 different stations on Clarke Road. Maintained a minimum of 2 operation lanes of traffic throughout construction and 3 during Rush Hour.
- Pre-drilling of over 1,000m of 250mm diameter temporary casing for spoil/reflow management & grout stability
- Spoil containment/management and disposal of up to 40m3 per day
- Verticality measurement of Jet grout columns
- Daily temporary road reinstatement
- Permanent road reinstatement
- Working adjacent to High Voltage overhead lines
See similar projects
Brightside Phases 1 and 3
The project involved various complex tasks such as drilling and installation of cased secant piles, excavation and offsite disposal of soil, installation of tie-back anchors, and shotcrete wall construction.
Learn moreKITS BLOCK - 1981 Macdonald Street, Vancouver
Matcon successfully completed bulk excavation, disposal of contaminated soils, and extensive shotcrete shoring, overcoming challenges posed by hard sandstone with dedicated overtime efforts to maintain the project schedule.
Learn more3619 - 3681 Arbutus Street
Matcon successfully navigated unique challenges, including Vancouver's winter weather and absorbent sandy soils, to complete bulk excavation and shoring, managing running groundwater and implementing face-saving measures within budget and on time.
Learn moreSeymour Village Phase 6
Matcon successfully executed excavation and shoring for the Seymour Village Phase 6 residential project, navigating challenges near active townhome communities with a focus on safety and minimal neighborhood impact.
Learn more